The infrared thermal imager uses an infrared detector and an optical imaging objective lens to receive the infrared radiation energy distribution pattern of the target to be reflected on the photosensitive element of the infrared detector so as to obtain an infrared thermal image, which is a heat image and the surface of the object. Distribution field corresponds. In layman's terms, an infrared camera converts the invisible infrared energy emitted by an object into a visible thermal image. The different colors above the thermal image represent the different temperatures of the measured object. The use of infrared cameras includes several major steps: 1, adjust the focal length The image curve can be adjusted after the infrared image is stored, but the focal length cannot be changed after the image is stored, and other cluttered heat reflections cannot be eliminated. Guaranteeing correct operation for the first time will avoid mistakes in the field. Carefully adjust the focus! If the overheating or cold reflection of the background above or around the target affects the accuracy of the target measurement, try adjusting the focal length or measuring the bearing to reduce or eliminate reflection effects. 2, select the correct temperature range Do you know the temperature measurement range of the measured object in the field? In order to obtain the correct temperature reading, be sure to set the correct temperature measurement range. When observing the target, fine-tuning the instrument's temperature span will yield the best image quality. This will also affect the quality of the temperature curve and the temperature measurement accuracy. 3, understand the maximum measurement distance When measuring the target temperature, be sure to know the maximum measurement distance that will give you an accurate temperature reading. For an uncooled microcalorimetric focal plane detector, the target image through the thermal imaging system must occupy 9 pixels or more in order to accurately resolve the target. If the instrument is too far from the target, the target will be very small and the temperature measurement result will not reflect the true temperature of the target object correctly because the temperature measured by the infrared camera at this time averages the temperature of the target object and the surrounding environment. To get the most accurate measurement reading, fill the target object with the instrument's field of view. Show enough scenery to be able to tell the goal. The distance to the target should not be less than the minimum focal length of the thermal system of the camera, otherwise it cannot be focused into a clear image. 4, only to generate a clear infrared thermal image, or at the same time require accurate temperature measurement What is the difference between this? A quantized temperature curve can be used to measure the temperature in the field, and it can also be used to edit a significant temperature rise. Clear infrared images are also very important. However, if during the working process, temperature measurement is required and a comparison and trend analysis of the target temperature is required, it is necessary to record all the objectives and ambient temperature conditions that affect the precise measurement of the temperature, such as emissivity, ambient temperature, wind speed and direction, and humidity. , heat reflection sources, etc. 5, a single work background For example, when the weather is cold, when working outdoors, you will find that most of the targets are close to the ambient temperature. When working outdoors, be sure to consider the effects of solar reflection and absorption on the image and temperature measurement. Therefore, some older models of infrared cameras can only perform measurements at night to avoid the effects of solar reflections. 6, to ensure the stability of the instrument during the measurement process Now all long wave NEC infrared cameras can achieve 60Hz frame rate, so in the process of shooting images, due to instrument movement may cause image blur. For best results, the thermal imager should be as stable as possible when freezing and recording images. When pressing the store button, it should be as light and smooth as possible. Even slight instrument shake may result in unclear images. It is recommended to use a support under the arm to stabilize, or place the instrument on the surface of the object, or use a tripod to keep it as stable as possible.
Hydraulic Trolley Lift:
Mini Manual Hand Lift is a lifting platform for transporting small items, and similar to the function of the forklift truck. Electric Manual Lifts has the advantages of small size, flexibility, strong maneuverability, and easy operation.
Only has the most basic handling function, pure manual control, the volume is small, the weight is light, the lifting platform does not have the lift function. More for simple goods handling.
By means of manual operation, the transportation of small amount of goods in small place is realized by hydraulic or electric driven way.
Hydraulic Trolley Lift Specifications Table:
Model
Lift Capacity
(kg)
Max. Height
(mm)
Min. Height
(mm)
Platform Size
(mm)
Weight
(kg)
Wheel Dia.
(mm)
GTT-15
150
720
220
700*450*36
46
Φ100*25
GTT-30
300
900
210
855*500*50
80
Φ125*40
GTT-35
350
1300
355
910*500*53
105
Φ125*40
GTT-50
500
900
285
815*500*53
115
Φ125*40
GTT-70
700
1500
445
1220*610*53
195
Φ125*40
GTT-75
750
990
420
1000*510*55
125
Φ147*50
GTT-100
1000
990
380
1016*510*55
140
Φ147*50
Application Area:
The Hydraulic Trolley Lift is mainly used in warehouses, workshop and other places where people need to lift medium weight goods. Hydraulic Single Scissor Lift Hand Pallet Truck is the ideal choice for super markets, malls and logistics warehousing companies.
If you have any questions, please contact with us directly. Hydraulic Trolley Lift are produced with High Quality and Good Appearance. Welcome you can visit our Factory. For inqury, Please send mail directly to us.
Hydraulic Trolley,Hydraulic Lifting Trolley,Hydraulic Trolley Lift,Lifting Trolley Jinan East Machinery Co.,Ltd. , https://www.jneastmach.com
Thermography principle and use of skills