The so-called retention time locking means that the retention time of a particular compound remains constant between different instruments and different columns (but the nominal stationary phase and the same phase). I. Overview The factors that determine the retention time are as follows: 1, the nature of the compound, the nature of the fixative solution. 2, operating conditions. That is, carrier gas flow rate, column temperature, capillary column specifications, and detector type. Second, explain in detail 1, carrier gas control For the same carrier gas, pressure and flow rate are the parameters that affect the retention time; Different manufacturers of pressure gauges and flowmeters have different manufacturing precisions, so when the pressure and flow of different instruments show exactly the same, the flow rate in the column is not the same; Now that there is an EPC, this problem has basically been solved; although the EPCs made by the same manufacturer cannot be strictly identical for each item, the difference is small, and this difference can be completely compensated by the automatic adjustment of the pressure. 2, temperature control The retention time is extremely sensitive to temperature. In the past, mercury temperature was used to measure the column temperature, and the reproducibility was obviously problematic. The temperature is now controlled by thermistors and electronic circuits, and the accuracy is greatly improved. The temperature reproducibility between different instruments is satisfactory. Even with a temperature difference of 0.5°C, we can re-establish the retention time by adjusting the column pressure. 3, column specifications Columns from different manufacturers, despite having the same nominal specifications, inevitably have non-uniform inner diameters, changes in the thickness of the fixed liquid film, and inaccuracies in the column length, which can cause retention time fluctuations. The same column will change during use, such as re-installation or due to column contamination cut off 1 ~ 2cm, if the other operating conditions remain unchanged, the retention time can not be reproduced. At present, the reproducibility of the column manufacturing of the same manufacturer is already quite high, and the chromatographic column of different manufacturers can't be fully reproduced, especially the polar column. However, if we use the same manufacturer's column, we can basically solve this problem. As for the change of column length, it can be compensated by adjusting the column front pressure. 4, the detector type Conventional detectors: work under normal pressure; MS: Work under high vacuum; AED: Work above atmospheric pressure (eg, 10 kPa). In this way, when comparing the results obtained with conventional detectors and MS or AED, the column pressure drop is different even if the precolumn pressure is exactly the same, and the retention time cannot be reproduced. With EPC, it is easy to keep the column pressure drop the same by adjusting the pressure. Third, the summary Through the above analysis, we can conclude that as long as the instrument's carrier gas and temperature control accuracy is high enough, as long as the column nominal specifications are consistent, we can compensate for small changes in operating parameters by adjusting the column front pressure to achieve retention times. This is the basis of RTL. (Article source Hengtianli Instrument Network)
The filter end caps have a variety of end cap types such as Dust Collector Filter End Caps, dust filter element cover, activated carbon filter element cover, oil filter element end caps, air filter element end caps, water filter element end caps, etc.
FAQ
Q1: Are you a factory? Filter End Caps,Dust Collector Filter End Caps,Filter End Caps For Dust Collector,Open Round Filter End Caps Anping County Dongjie Wiremesh Products Co., Ltd. , https://www.dongjiewiremesh.com
At the same time, it can also be divided into square filter end caps, round filter end caps, Open Round Filter End Caps, special-shaped filter end caps, and other types;
According to the material, it can be divided into galvanized filter end caps, aluminum filter end caps, stainless steel filter end caps, and anti-fingerprint filter end caps. etc.
If you don't know this aspect, don't worry, you just need to tell us your use environment and its requirements, and our professional team can make a recommendation that is most suitable for you.
A1: Yes, we are a professional manufacturer of wire mesh products focusing on wire mesh for decades.
Q2: How can I get a quotation?
A2: You need to provide material, sheet size, wire diameter, hole distance, and quantity for inquiry. Special requirements can also be specified.
Q3: Is it ok if I want free samples?
A3: Yes, we can provide free samples in 20cm-50cm sizes along with our catalog. But the express fee will be on your account. If you place an order, we will refund the courier fee.
Q4: What's your payment term?
A4: Generally, our payment terms are T/T 30% advance payment, balance 70% against copy of B/L. We can also discuss other payment terms.
Q5: How about your delivery time?
A5: 1. We always prepare enough stock materials for your urgent needs, and the lead time for all stock materials is 7 days.
Depending on quantity and technology, exact lead times and production schedules for non-stock items will be communicated to you.
Introduction to Determinants of Chromatographic Retention Time